1. After running for 200~300 hours, the oil should be changed for the first time, and the oil quality should be checked regularly in future use, and the oil mixed with impurities or deterioration should be replaced in time. Under normal circumstances, the reducer that works continuously for a long time should be replaced with new oil after running for 5000 hours or once a year, and the reducer that is stopped for a long time should also be replaced with new oil before re-running. The reducer shall be added with oil of the same brand as the original one, and shall not be mixed with oil of different brands. Oils of the same brand and different viscosities are allowed to be mixed.

2. When changing oil, wait for the reducer to cool down without burning danger, but keep it warm, because the viscosity of oil increases after complete cooling, making it difficult to drain oil. Attention: cut off the power supply of the transmission device to prevent inadvertent energization;

3. During work, when it is found that the oil temperature rises above 80℃ or the oil pool temperature exceeds 100℃ and abnormal noise is generated, it should be stopped. Check the reasons, eliminate the faults, and replace the lubricating oil before continuing to operate;

4. Users should have reasonable use and maintenance rules and regulations, and carefully record the operation of speed reducer and the problems found during inspection. The above provisions should be strictly implemented.


Tel:+86-577-65555560 65555580    Fax:0577-65555570    Contact:Manager Chen    Add:Gexiang Industrial Zone, Nanbin Street, Ruian, Zhejiang    Website:http://www.wzruitong.com